NEW Direct Replacement 17.5µF (microfarad/MFD)±
5%, 440-VAC Motor Run Capacitor with Internal Bleed Resistor for 1/3 and 3/4HP
Red Jacket® Submerged Turbine Pumps (STPs)
Directly Replaces
Red Jacket
®
Capacitor Part Number
012-580-1, and
the Capacitor in Red Jacket
®
Kit Part Numbers
111-092-5 and 410-164-001
Our 17.5µF 440-VAC Motor Run Capacitors
(Part Number 41817-20)
are
proudly manufactured in the United States of America using high quality domestic and globally sourced materials, and contains an Internal Bleed Resistor*, as required by Red Jacket
®
, Underwriters Laboratories Inc. (UL), and prevailing code.
Further, the Capacitor is specifically designed as the
ultimate
replacement for the Capacitor in Red Jacket
®
Kits
111-092-5 and 410-164-001, and
Red Jacket
®
Capacitor
012-580-1, which are used in early and late production 1/3HP and 3/4HP Red Jacket
®
STPs.
We are so confident in the quality crafted into our 17.5-µF Capacitors, each comes with a 2-Year Warranty.
*Internal Bleed Resistor safely depletes the energy stored in the Motor Run Capacitor once the main power source is disconnected from the STP, thereby rendering the Capacitor incapable of becoming an ignition source; which is particularly critical when in an explosive atmosphere (e.g., STP sump, STP manhole, etc.).
DO NOT INSTALL A GENERIC (NON BLEED RESISTOR) MOTOR RUN CAPACITOR
in a
Red Jacket
®
STP!
Potential consequences of installing a generic capacitor in an STP include:
~ property damage, injury and/or death caused by fire and/or explosion;
~ penalties by Local, State and/or Federal authorities having jurisdiction (e.g., “Occupational Safety and Health Act of 1970");
~ voiding of STP warranty, due to the installation of an improper replacement component; and
~ increasing sparking and arcing of the contacts in the STP’s Line Contactor Relay (e.g., Red Jacket
®
Part Numbers 017-061-1 and 014-723-1), thereby decreasing the reliability and service life of the Relay.
~ DO NOT install a 25
µF Motor Run Capacitor in a 1/3HP or 3/4HP STP. Doing so, will increase motor noise and shorten the service-life of the STP.
Our 17.5µF Motor Run Capacitor is
proudly
manufactured in the United States of America and is UL certified, Canadian Standards Association (CSA) 222.2 No. 190 recognized, and Electronic Components Industry Association (ECIA) EIA-456-A compliant. In addition,
our Motor Run Capacitor is packaged with a comprehensive Product Data Sheet, specifically developed to inform and educate service personnel on capacitor handling and installation practices. Further, each
Motor Run Capacitor is individually packaged in a durable, size appropriate, labeled (i.e., pert number and description) corrugated box, constructed of a three layer cardboard material (paper sheet on both sides of a rigid fluted core), ideally suited for warehousing and service vehicle applications.
Additional features of our Motor Run Capacitor include, but are not limited to the following*:
• Capacitor Type: Metalized Polypropylene Film with Self-Healing Properties
• Operating Voltage: 440-Volts Alternating Current (VAC)
• Operating Frequency:
50/60 Hertz (Hz)
• Capacitance Tolerance:
± 5%
• Internal Failure Protection:
Open Circuit State
• Internal Bleed Resistor: High Power Metal Film Resistor, Encapsulated in a Non- Flammable, Coated Ceramic Body
• Capacitor Case:
Extruded Aluminum
• Capacitor Case Top:
Stamped Tin-Plated Steel with Moisture and Oil Resistant Bead with a Rolled Crimp
• Capacitor Dimensions w/Terminals:
~4.38” (~111.25mm) Tall x ~1.76” (~44.7mm) Diameter
• Terminal Type:
Dual .25” (6.35mm) Wide Push Type Male Tab/Blade
• Operating Temperature Range:
-40º Celsius (-40º Fahrenheit) to +70º Celsius (+158º Fahrenheit)
• Coolant Composition/Heat Transfer Fluid: Non-Petroleum Based
PCB Free
Oil
*Specifications subject to change without notice.
We are proud to provide quality products and services, and want your transaction to be pleasant and satisfying. If you have a question or concern, please contact one of our Customer Service Representatives, through eBay's messaging portal, Monday through Friday, 8:00am to 5:00pm [Eastern Standard Time (EST)], excluding holidays. In addition, please review the following General Policies. If there are any questions, please contact us before committing to a purchase.
General Policies:
Payment:
Payments are to be made through eBay’s PayPal portal. Manual payments made directly through PayPal will not be accepted.
Payments are to be made within 3-days after committing to the purchase. If a payment is not made within 3-days, the transaction will be considered “null and void” due to non-payment.
Only payments from confirmed addresses will be accepted.
Shipping:
Purchases will be delivered by USPS Priority Mail with accompanying USPS Tracking Number.
Purchases will be shipped to confirmed addresses only (Sorry, but shipments to P.O. Boxes or military APO's are not accepted at this time).
Delivery to Puerto Rico and other off-shore US locations and territories is available at an additional fee. Please contact one of our Customer Service Representatives through eBay's messaging portal for additional information.
Purchases paid for before 1:00pm EST Monday through Friday (excluding holidays), typically ship the same day. However, if a purchase does not ship the same day, the purchase will ship the following business day.
The Seller is responsible for any wrong or un-deliverable address provided. In the event that a shipment is made to a confirmed but un-deliverable address, the returned item will be reshipped at an additional fee.
If the shipping company (i.e., USPS) fails for any reason to fulfill their obligation to deliver the item(s) purchased in the estimated time specified, the Seller shall not be held liable for any punitive, indirect, special, incidental, or consequential damages.
If an item is required faster than what USPS Priority Mail provides, the Buyer can contact one of our Customer Service Representatives through eBay's messaging portal for expedited shipping options.
Local pick up is available by pre-arrangement.
Returns:
Each Capacitor(s) is inspected and tested prior to shipment. In the unlikely event that a Buyer receives a damaged or otherwise defective Capacitor, the Buyer is to report the damage and/or defect to the Seller within 24-hours of receipt.
Returns for reasons other than a Warranty exchange require that the Buyer agrees to: 1) obtaining a Return Materials Authorization (RMA) Number from the Seller within 14-days of purchase; 2) returning the new, unused item and its original product packaging; 3) clearly printing the RMA Number on the outside of the shipping package; 4) conveying the packaged item to the shipper within 3-calendar days (excluding holidays) following issuance of the RMA Number; 5) shipping, insuring and tracking the shipment back to the Seller; 6) a 20% restocking fee; and 7) up to 3-business days (excluding holidays) for the Seller to process a refund.
Any item returned without an RMA Number conspicuously printed on the outside of the shipping container will be refused and returned to the Buyer.
Warranty:
Our Motor Run Capacitors are warranted to be free of defects in materials and workmanship to the original Buyer, for a period of 2-years and 1-week (105-weeks) commencing on the date of shipment.
Warranty does not cover altered Motor Run Capacitors, nor Capacitors which are damaged in any manner by the Buyer or others, nor damage due to improper installation, nor damaged due to installing the Capacitor in an improper application.
Warranty specifically pertains to a Motor Run Capacitor that has a defect in material(s) or workmanship, which developed under normal and proper use. Subsequently, defects related to improper electrical connections and/or improper installation and/or modification(s)/alteration(s) are not eligible to receive a replacement Motor Run Capacitor under Warranty.
All Warranty claims must be made within 2-years from the date that the Motor Run Capacitor(s) was shipped to the Buyer. Warranty claims submitted after this period will not considered.
A Motor Run Capacitor(s) replaced under Warranty will be covered by the remaining Warranty balance on the original Motor Run Capacitor(s) purchased.
If a Motor Run Capacitor is thought to be defective or otherwise fails to perform during the Warranty period, report the problem immediately to the Seller via eBay’s message portal, and request a Return Materials Authorization (RMA) Number and return shipping label from the Seller. When messaging the Seller to obtain an RMA Number and shipping label, also provide the Seller with: 1) the reason(s) for the Warranty claim; 2) photo(s) depicting the Motor Run Capacitor(s) defect, if applicable; 3) the eBay Item Number for the Motor Run Capacitor purchased; and 4) the PayPal transaction number for the Motor Run Capacitor purchased.
A Motor Run Capacitor will not be considered defective under Warranty if the Capacitor fulfills the performance standards and characteristics detailed in the specifications.
After obtaining an RMA Number from the Seller, the Buyer is responsible for: 1) packaging the Motor Run Capacitor in an appropriately sized and packed shipping container with the RMA Number conspicuously and clearly written on the container; and 2) conveying the shipping container to the delivery service identified on the provided shipping label.
Upon receipt of a Motor Run Capacitor(s) by the Seller, the Seller will determine, at their sole discretion, if the Motor Run Capacitor(s) has a defect in material(s) or workmanship, or if the Capacitor(s) failed for another reason [e.g., improper electrical connection and/or improper installation and/or modification(s)/alteration(s), misuse, misapplication, abuse, over-voltage, lightning strike, etc.].
If a Motor Run Capacitor(s) has a defect in material(s) or workmanship, a replacement Capacitor(s) will be shipped to the Buyer free of charge, within 1-business day, via USPS Priority Mail, following receipt of the defective Motor Run Capacitor, which will become the property of the Seller. Conversely, if the Seller determines that the cause of the failure was not due to a defect in material(s) or workmanship [e.g., improper electrical connection and/or improper installation and/or modification(s)/alteration(s), misuse, misapplication, abuse, over-voltage, lightning strike, etc.], the Seller will notify the Buyer via eBay’s message portal within 1-business day. If this becomes the case, the Motor Run Capacitor is not eligible for replacement under the terms of the Warranty.
Any costs associated with the installation of a Motor Run Capacitor, or any alleged damages caused, or alleged costs incurred due to a Motor Run Capacitor(s), are limited to the purchase price of the Motor Run Capacitor(s). Further, the Warranty is exclusive and is in lieu of all other warranties of merchantability, fitness for a particular purpose or any other type of warranty whether expressed or implied.
Limitations of Liability:
In no event shall Seller be liable for punitive, indirect, special, incidental, or consequential damages, including, but not limited to, loss of revenue or profit, loss of product use or equipment, damage to associated equipment, cost of capital, cost of substitute products, downtime costs, or other claims of Buyer or their customer(s) for such damages or any other damages in an amount exceeding the price that the Buyer paid for the Motor Run Capacitor including
USPS Priority Mail
shipping.
If Seller furnishes Buyer with information, advice or other technical assistance without separate compensation, the Seller will not be subject to any liability, and the Buyer agrees to hold Seller harmless and indemnify Seller from any liability in connection with the information, advice or other technical assistance provided, including, but not limited to attorneys’ fees and expenses, expert witness fees and expenses, and court costs.
Contact Us:
Thank you in advance for allowing us the opportunity to be of service. If you have any questions, please contact one of our Customer Service Representatives through eBay’s messaging portal, Monday through Friday, 8:00am to 5:00pm EST, excluding holidays.
Feedback
:
If you are not satisfied with a purchase for any reason, please contact us via eBay’s Message portal to allow us an opportunity to address your needs, before leaving neutral or negative feedback. Otherwise, please leave positive feedback with 5 stars.
Disclaimer
:
The Veeder-Root Company
©
and Red Jacket
®
are names provided for reference only. Further, the name Red Jacket
®
is a registered Trademark of The Veeder-Root Company
©
, both of which have no affiliation or connection in any way to the Motor Run Capacitor described herein. Additionally, The Veeder-Root Company
©
and the Red Jacket
®
names are the exclusive property of their respective owners.
Safety First
:
As with any product, there is information that service providers and others should know before replacing a Motor Run Capacitor. In an effort to educate our eBay patrons, the following Safety First section is presented for review. The information in this section is not intended to be absolute nor does it include all eventualities or circumstances, but it is provided to highlight activities that may require consideration before and after replacing a Motor Run Capacitor, and the level of risk associated with an activity.
Safety First Definitions
:
IMPORTANT
: Attention required to avoid damaging equipment or the environment. For example, fuel leakage from damaged equipment could negatively impact the environment, or present fire or explosion hazards.
CAUTION
: Using improper procedures or practices that could result in personnel injury.
WARNING
: Unsafe conditions associated with improper procedures or practices that could result in significant injury including death.
DANGER
: Immediately hazardous conditions that can result in death.
Safety First Activities
:
IMPORTANT
: The Motor Run Capacitor is hermetically sealed and contains no serviceable components. If a Motor Run Capacitor fails, consult Local, State and Federal codes regarding proper disposal.
IMPORTANT
: A Red Jacket
®
STP requiring a new Motor Run Capacitor may be located in close proximity to volatile vapors and/or liquids typically associate with motor fuels or other volatile fuels or chemicals. In consideration that volatile vapors and liquids are capable of supporting a fire and/or producing an explosion, recognized industry standards [e.g., Local, State and Federal laws/codes, Red Jacket
®
guidance/instruction documents (e.g., Bulletin RJ-23-41, etc.), National Fire Protection Association publications 30, 30A, 70, etc.] are to be followed when replacing a Motor Run Capacitor.
IMPORTANT
: When replacing a Motor Run Capacitor, inspect the STP for damage and missing parts, and ensure that the Motor Run Capacitor compartment is free of liquids. In addition, ensure that the O-Ring sealing the Capacitor compartment is either replaced or determined to be acceptable for reuse.
CAUTION
: Do not solder directly to the terminals on the Motor Run Capacitor. If soldering is performed, the liquid tight seal between the Capacitor Case Top and terminals may leak and/or the connections inside of the Capacitor may fail creating the potential for a fire and/or explosion.
CAUTION
: Personnel injury or property damage may result if a Motor Run Capacitor fails due to a mechanical or electrical disruption. Subsequently, in the event of a failure, an explosion and/or expulsion of Coolant/Heat Transfer Fluid could occur. Contact with Coolant/Heat Transfer Fluid and/or related vapors are to be avoided. In the event of accidental contact with the skin, eyes or oral ingestion, actions may be required as follows:
Skin Contact
: May cause irritation, flush and wash thoroughly with soap and water immediately.
Eye Contact
: May cause irritation, contact lenses must be removed immediately; after which, the open eye(s) should be immediately flushed with large amounts of water. Seek medical attention if irritation persists.
Oral Ingestion
: As an interim emergency measure, administer warm water or milk to rinse mouth. Do
not
induce vomiting unless directed by medical personnel, and immediately seek medical attention.
Vapors
: Avoid inhalation of vapors, ventilate area thoroughly and go to fresh air. If breathing difficulties are present, seek medical attention.
WARNING
: Always secure the work area surrounding an STP by deploying appropriate barricades, to alert others of the work in process and protect service personnel from vehicular traffic.
DANGER
: Follow all Local, State and Federal codes pertaining to the installation of a Motor Run Capacitor which includes Lock-Out and Tag-Out protocols (e.g., 29 Code of Federal Regulations Part 1910.147) of electrical circuit(s) and other energy sources associated with an STP and related equipment. If an electrical circuit breaker(s) is left in the “ON” position, a potentially lethal electrical shock and/or spark could result, and provide an ignition source for a fire and/or explosion. Never turn “ON” or otherwise energize an electrical circuit(s) or other energy source until all service work is performed and all equipment covers are properly reinstalled. For additional and more complete safety information, refer to Red Jacket’s
®
STP Service Manual,
Red Jacket’s
®
Service and Parts Manual 577013-830 and other related documentation.
DANGER
: Before entering an STP containment sump (e.g., to replace a Motor Run Capacitor, etc.), implement Permitted Required Confined Space Entry or Non-Permit Required Confined Space Entry procedures, as appropriate, per 29 Code of Federal Regulations Part 1910.146, to avoid potential hazards (e.g., inhalation, entrapment, electrocution, etc.) associated with Confined Spaces.
DANGER
: Prior to replacing a Motor Run Capacitor that is either known to not be equipped, or is suspected of not being equipped with an Internal Bleed Resistor - deplete the electrical potential stored in the Capacitor (e.g., connection of an appropriately sized and designed external Resistor-Shunt or other appropriate method) prior to removal. To prevent a potential shock hazard, and/or fire/explosion hazard, it should
never
be assumed that a Capacitor is adequately depleted or otherwise discharged until tested and verified.
Proposition 65 Warning
:
Proposition 65 requires that businesses display a Warning for listed chemicals unless exposure is low enough to pose “no significant risk” of cancer to the user or is significantly below levels observed to cause birth defects or other reproductive harm. By means of the Proposition 65 Warning protocol, Californians are provided with information to make informed decisions about the products they purchase and use. However, please note that products with the Proposition 65 label, does not necessarily classify a product as being in violation of any product safety standards or requirements, because Proposition 65 is more of a “Right-to-Know” law than an actual product safety law.
Based on the above, ACS, Inc. has elected to display the Proposition 65 warning on select products based on the possible presence of one or more listed chemicals. Although exposure from our products may not exist, or may be negligible, or may be well within a “no significant risk” level to the user, the actual level of exposure has not been assessed. In consideration that our Motor Run Capacitors are intended to be installed inside of a sealed housing, the end user has no risk of exposure. However once testing is performed, ACS, Inc. may elect to curtail Proposition 65 warnings altogether, where the level of exposure has been conclusively quantified as being under acceptable published limits.